Table 39: Power Supply Faceplate LEDs (continued)
Possible Cause and Corrective
Action
Meaning
Color
LED
Label
Power
Supply
Type
Normal indication. No action is
required.
The DC output voltages produced
by the power supply are within
tolerance.
Green
DC OK
DC
One or more of the DC output
voltages produced by the power
supply are outside of tolerance.
Red
The power supply is not receiving
input power.
Unlit
Normal indication. No action is
required.
The DC input power provided to
the power supply is within
tolerance.
Green
INPUT
OK
The DC input power provided to
the power supply is outside of
tolerance.
Amber
The power supply is not receiving
input power.
Unlit
RELATED DOCUMENTATION
SRX550 Services Gateway Front Panel | 15
Troubleshooting with the CLI on the SRX550 Services Gateway | 125
Troubleshooting with LEDs on the SRX550 Services Gateway | 126
Changing the RESET CONFIG Button Behavior on the SRX550 Services Gateway | 136
Using the RESET CONFIG Button on the SRX550 Services Gateway
If a configuration fails or denies management access to the services gateway, you can use the RESET
CONFIG button to restore the services gateway to the factory default configuration or a rescue
configuration. For example, if someone inadvertently commits a configuration that denies management
134
Summary of Contents for SRX550
Page 1: ...SRX550 Services Gateway Hardware Guide Published 2020 12 16...
Page 55: ...39...
Page 178: ...162...
Page 182: ...Restricted Access Warning 166...
Page 196: ...Jewelry Removal Warning 180...
Page 199: ...Operating Temperature Warning 183...
Page 206: ...190...
Page 210: ...194...
Page 213: ...197...