![Juniper SRX550 Hardware Manual Download Page 149](http://html1.mh-extra.com/html/juniper/srx550/srx550_hardware-manual_2032212149.webp)
Table 39: Power Supply Faceplate LEDs
Possible Cause and Corrective
Action
Meaning
Color
LED
Label
Power
Supply
Type
Normal indication. No action is
required.
The DC output voltages produced
by the power supply are within
tolerance.
Green
DC OK
AC
One or more of the DC output
voltages produced by the power
supply are outside of tolerance.
Red
The power supply is not receiving
input power.
Unlit
Normal indication. No action is
required.
The AC input power provided to
the power supply is within
tolerance.
Green
AC OK
The AC input power provided to
the power supply is outside of
tolerance.
Amber
The power supply is not receiving
input power.
Unlit