4. Insert the power cord plug into an external AC power source receptacle.
NOTE:
Each power supply must be connected to a dedicated AC power feed and a dedicated
external circuit breaker. We recommend that you use a 15 A (250 VAC) minimum, or as
permitted by local code.
Figure 22: Connecting an AC Power Cord
5. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and
access to services gateway components or drape where people could trip on it.
NOTE:
The services gateway must be connected to earth ground during normal operation. The
protective earthing terminal on the side of the chassis is provided to connect the services gateway
to ground.
CAUTION:
We recommend using a surge protector for the power connection.
RELATED DOCUMENTATION
Preventing Electrostatic Discharge Damage to the SRX550 Services Gateway
Grounding the SRX550 Services Gateway | 77