PzV and PzV-BS lead-acid batteries with sealed armour
plated cells
5.1
Description
PzV batteries are sealed batteries with fixed electrolytes, to which no water can be
added over the entire lifespan of the battery. Relief valves are used as plugs which
are destroyed when opened. During operation the same safety requirements apply to
the sealed batteries as for batteries with liquid electrolyte. This is to avoid electric
shock, explosion of the electrolyte charging gases or hazardous electrolyte burns if
the cell vessels are destroyed.
Z
PzV batteries are low gassing, but not gassing-free.
Electrolyte
The electrolyte is sulphuric acid which is fixed in gel. The density of the electrolyte
cannot be measured.
5.1.1 Battery nominal data
Name
Explanation
PzV
– Lead acid battery with "Standard" closed armour plated cells
and electrolyte in gel compound
– Battery cell width: 198 mm
PzV-BS
– Lead acid battery with "British Standard" closed armour plated
cells and electrolyte in gel compound
– Battery cell width: 158 mm
1.
Product
Traction battery
2.
Nominal voltage
2.0 V x number of cells
3.
Rated capacity C5
See data plate
4.
Discharge current
C5/5h
5.
Rated temperature
30°C
Limit temperature
1
1. Higher temperatures shorten the useful life, lower temperatures reduce the
available capacity.
45°C, not permissible as operating
temperature
6.
Rated density of the electrolyte
Cannot be measured
7.
System rated electrolyte level
Cannot be measured
Summary of Contents for EFX 410
Page 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 72: ...70 04 19 en GB ...
Page 90: ...88 04 19 en GB ...
Page 250: ...248 04 19 en GB ...
Page 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Page 376: ......
Page 380: ...02 16 EN 6 ...
Page 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 404: ......