2.5.1
Percentage display battery discharge monitor (
o
)
Z
If a battery is discharged to less than 31 % for wet-cell batteries or 41 % for gel
batteries (residual capacity), the battery symbols flashes in the driver's display. The
load handler can no longer be lifted below 21 % for wet-cell batteries and 31 % for
gel batteries.
Battery discharge monitor for wet-cell batteries:
Battery symbol Percentage
Meaning
Permanently lit
100 % - 31 %
Battery is charged.
– The higher the percentage, the greater the
battery residual capacity.
Flashing
30 % – 21 %
Battery charge recommended.
20 % – 0 %
Battery charge required (charge is below
residual capacity level).
– The load handler can no longer be lifted.
The lift function is disabled by the controller.
Z
Raising is only enabled when the battery connected is at least 40 % charged.
Battery discharge monitor for gel batteries:
Battery symbol Percentage
Meaning
Permanently lit
100 % – 41 %
Battery is charged.
– The higher the percentage, the greater the
battery residual capacity.
Flashing
40 % – 31 %
Battery charge recommended
30 % – 0 %
Battery charge required (charge is below
residual capacity level).
– The load handler can no longer be lifted.
The lift function is disabled by the controller.
Z
Raising is only enabled when the battery connected is at least 50 % charged.
107
04.19 en-GB
Summary of Contents for EFX 410
Page 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 72: ...70 04 19 en GB ...
Page 90: ...88 04 19 en GB ...
Page 250: ...248 04 19 en GB ...
Page 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Page 376: ......
Page 380: ...02 16 EN 6 ...
Page 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 404: ......