Display Error
Description
220 &222
Incorrect rack (height)
entered with order
– Check entry.
– The "question mark" and "rack
(height)" symbols flash alternately.
219
Wrong position in narrow
aisle (transponder not
detected)
– Aisle start, end or centre transponder
must be passed over again.
– The "location/marker" and the lightning
symbol flash alternately.
223
Position in the narrow aisle
not detected; tolerance
exceeded
212 &221 No load when retrieving
– The stacking operation is performed
until the attachment is in the home
position.
– The warning symbol lights up.
221
Incorrect checksum on data
entry
– The order cannot be carried out.
– Re-enter the data or amend the order.
– The warning symbol flashes until the
order is deleted.
---
Orders cannot be entered as
there is already an order in
the memory.
– The order entry is blocked.
– Carry out the existing order.
---
Faulty data transmission
– The order is not accepted.
– The error number is displayed.
---
Data transmission not
repeated despite error
recognition (NAK)
– The order is not accepted.
– The error number is displayed.
---
Incorrect checksum
– The order cannot be carried out.
– Re-enter the data or amend the order.
286
04.19 en-GB
Summary of Contents for EFX 410
Page 1: ...EFX 410 413 03 13 Operating instructions 51296679 04 19 en GB EFX 410 EFX 413 ...
Page 2: ...2 ...
Page 4: ...4 04 19 en GB ...
Page 12: ...0506 GB 2 0506 GB 2 ...
Page 72: ...70 04 19 en GB ...
Page 90: ...88 04 19 en GB ...
Page 250: ...248 04 19 en GB ...
Page 261: ...The Operator specific settings menu now opens 259 04 19 en GB ...
Page 376: ......
Page 380: ...02 16 EN 6 ...
Page 382: ...02 16 EN 8 14 Safety instructions and warning information ...
Page 404: ......