– 157 –
<Condensation custom pattern list screen>
1. In the case of setting the number of
stitches
Condensation custom pattern input
procedure is described as follows using
< Figure: Example of the condensation
custom pattern > as an example.
The number of stitches can be input in
the range from 1 to 100.
Set the number of stitches for step 1 to 3
with numeric keypad
❽
❾
.
Press
to confirm the setting.
2. In the case of setting the stitch length
Possible input range is same as that of "S003 Stitch length".
Set the stitch length for step 1 to 1.0 mm using numeric keypad
and
.
Press
to confirm the setting.
A negative number of stitches can also be set. In this case, the direction of feed is reverse direction.
3. Carry out the following setting in the similar manner.
The number of stitches for step 2: 4 stitches
Stitch length for step 2: 1.5 mm
The number of stitches for step 3: 3 stitches
Stitch length for step 3: 1.0 mm
The number of stitches for step 4: 3 stitches
Stitch length for step 4: -1.0 mm
The number of stitches for step 5: 2 stitches
Stitch length for step 5: 1.5 mm
⑤
Confirming the numeric value
Press
to confirm the setting.
<Condensation custom pattern list screen>
<Condensation custom edit screen>
The condensation custom list screen is
displayed with the condensation custom
number you have created added.
❽
❾
Summary of Contents for SC-956
Page 1: ...INSTRUCTION MANUAL LH 4500C Series SC 956...
Page 180: ...175 11 GAUGE PARTS LIST 43 22 TABLE OF EXCHANGING GAUGE PARTS LH 4578C TYPE F LH 4578C F type...
Page 181: ...176 23 TABLE OF EXCHANGING GAUGE PARTS LH 4578C 7 LH 4578C 7...
Page 182: ...177 47 24 TABLE OF EXCHANGING GAUGE PARTS LH 4588C 7 LH 4588C 7...