– 103 –
7-3. Replacing the fuse
The machine uses the following two fuse.
Both are the same fuses.
CTL PCB
❶
For 85V power supply protection
5A (time-lag fuse)
❷
For 24V power supply protection
5A (time-lag fuse)
❶
❷
7-2-2. Applying grease to the presser bar bushing
1) Remove presser bar bushing lubrica-
tion screw
❷
with a hexagon wrench.
2) Detach the cap of exclusive grease
❶
.
Put its tip into the oil hole to add exclu-
sive grease
❶
.
At this time, add the grease until it over-
flows.
3) Push in overflowing exclusive grease
❶
with lubrication screw
❷
.
4) Wipe off the excess of exclusive grease
❶
(from around the lubrication screw).
❷
DANGER :
1.
To avoid electrical shock hazards, turn OFF the power and open the control box cover after about
five minutes have passed.
2.
Open the control box cover after turning OFF the power without fail. Then, replace with a new
fuse with the specified capacity.
❶