– 8 –
1) Attach the terminals of power cord
❶
coming
from the electrical box to reactor box PCB
asm.
❷
and reactor box mounting plate
❸
.
Connect brown wire
A
to the first connector
and blue wire
B
to the third connector respec-
tively from the top of terminal block on the
reactor box PCB asm. using screws. Connect
green/yellow wire
C
to reactor box mounting
plate
❸
with earth setscrew
❹
.
2) Attach cable clip
❺
to the power cord com-
ing from the electrical box. Then, attach the
power cord together with the cable clip to
reactor box mounting plate
❸
with cable clip
setscrew
❻
.
3) Attach cord bushes
❽
to input/output cables
❶
and
❼
of the reactor box. Attach both
bushes in the same manner.
4) Attach reactor box cover
to reactor box
mounting plate
❸
with four reactor-box cover
setscrews
❾
.
At this time, fix cord bushes
❽
attached to
input/output cables
❶
and
❼
in the concave
section on reactor
box cover to eliminate a
gap between reactor box
and cover
.
5) Secure reactor box
to the undersurface of
table with four accessory wood screws
.
6) Secure two cables
coming from reactor
box
to the table with accessory cable clip
and wood screw
.
❼
❽
❽
❶
❾
❽
❸
❸
❶
❷
❹
A
B
❻
❺
C
❾
2-7. Installing the reactor box (Only for the EU type models)
2-8. Connecting the power switch cable
Fix power switch
❶
under the machine table with
wood screws
❷
.
Fix the cable with staples
❸
supplied with the ma-
chine as accessories in accordance with the forms
of use.
2-8-1. Installing the power switch
❶
❷
❸
Electrical box
(EU type models:
Reactor box)
Summary of Contents for SC-956
Page 1: ...INSTRUCTION MANUAL LH 4500C Series SC 956...
Page 180: ...175 11 GAUGE PARTS LIST 43 22 TABLE OF EXCHANGING GAUGE PARTS LH 4578C TYPE F LH 4578C F type...
Page 181: ...176 23 TABLE OF EXCHANGING GAUGE PARTS LH 4578C 7 LH 4578C 7...
Page 182: ...177 47 24 TABLE OF EXCHANGING GAUGE PARTS LH 4588C 7 LH 4588C 7...