Victorum Exhaust Air Heat Pump Installation Guide
49
Victorum Compact
Transport and Handling
The Victorum Compact unit is delivered
fully packaged and fixed to a wooden
pallet base. Care should be taken when
transporting the unit ensuring that the
casing is not damaged by impact.
At least two people should lift the unit to
prevent injuries. The unit must be stored
in a dry area and must never be dropped
during handling. Packaging should only be
removed at the installation location. This will
help protect the casing and components.
The unit must be installed on a level floor
with the required load bearing capability.
Suitable Location
Care should be taken that the recommended minimum distance around the unit for service and
maintenance works to be carried out, are adhered to. Access to allow maintenance of the valves
should be considered. In addition, the immersion heater is 400mm in length and this distance should
be considered.
When using the adjustable feet, ensure that the floor is
strong enough. Install the unit where it is not exposed
to water/excessive moisture. Particular attention is
needed if sitting in a garage or outbuilding as the unit
should be protected from frost. All exposed pipework
must be insulated. The unit must be installed upright
on a base capable of supporting its weight when full
(please see the technical specification section for
weights).
Both pallets must be transported in an upright position only.
Transporting the unit
The side clearances stated as 300mm
can be reduced to 10mm as long as
the object inside of the 300mm space
is removable to allow access for service
and/or maintenance works. An example
would be a removable panel that allows
sufficient access to the top, front or
sides of the unit.
300m
m
300m
m
450m
m
10
mm
10
mm
10
mm