Victorum Exhaust Air Heat Pump Installation Guide
81
Victorum Combi
Overview
Connecting the Outdoor Sensor
The Outdoor Sensor monitors the outside air
temperature and is installed on the exterior of
the dwelling on a north facing wall, if possible.
Otherwise, the sensor must be kept away from
direct sunlight.
The exterior wall material must be considered,
as materials like Zinc can act as a heat sink.
This can affect the senor reading, producing
higher readings.
The outdoor sensor requires a two core
0.75mm2 cable and it is not polarity sensitive.
The sensor is connected to ‘B1’ and ‘Gnd’ on the
controller.
Connect the Positive (+) and Negative (-)
respecting the polarity at both the touchscreen
and transformer.