Model: Joule Victorum 62010200
Variant models: Victorum 7784292, 62210018, 62210022
Air-to-water heat pump: Yes, Exhaust Air Heat Pump
Water-to-water heat pump: No
Brine-to-water heat pump: No
Low-temperature heat pump: No
Equipped with supplementary heater: Yes
Heat pump combination heater: Yes
Parameters are declared for: Low-temp application,
35°C
Harmonised standards applied: EN14511:2013, EN14825:2016, EN16147:2017, BS EN3743-1:2010
Parameters are declared for:
Average
climate conditions
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
2.0
kW
Seasonal space heating energy efficiency
ɳ
s
196
%
Tj = -7
⁰
C
Pdh
1.8
kW
Tj = -7
⁰
C
COPd
5.53
-
Tj = +2
⁰
C
Pdh
1.9
kW
Tj = +2
⁰
C
COPd
5.74
-
Tj = +7
⁰
C
Pdh
1.9
kW
Tj = +7
⁰
C
COPd
5.78
-
Tj = +12
⁰
C
Pdh
1.8
kW
Tj = +12
⁰
C
COPd
5.81
-
Tj = bivalent temperature
Pdh
1.9
kW
Tj = bivalent temperature
COPd
5.74
-
Tj = operation limit temperature
Pdh
1.8
kW
Tj = operation limit temperature
COPd
5.53
-
Pdh
-
kW
Pdh
-
-
Tbiv
2
⁰C
TOL
-10
⁰C
Pcych
-
kW
COPcyc
-
-
Cdh
0.9
-
WTOL
60
⁰C
Off mode
P
OFF
0.058
kW
Rated heat output (*)
P
sup
3
kW
Thermostat-off mode
P
TO
0.058
kW
Standby mode
P
SB
0.054
kW
Type of energy Input
electrical
Crankcase heater mode
P
CK
0.000
kW
Capacity control
155
m
3
/h
L
WA
59/-
dB
-
-
m
3
/h
NO
X
-
mg/kWh
For heat pump combination heater:
Declared load profile
ɳ
wh
-
%
Daily electricity consumption
Q
elec
-
kWh
Q
fuel
-
kWh
Contact details
Applicable date:
Revision:
Document Control No.
-
Water heating energy efficiency
Daily fuel consumption
4.0
25/01/2021
Precautions as described in the installation/user manual must be taken when assembling, installing, maintaining, disassembly, recycling and/or disposal at end-of-life of this product.
Joule Ireland, Unit 407 North West Business Park, Cappagh Road, Dublin 11, Ireland. D11 HD36
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output
Prated
is equal to the design load for heating
Pdesignh
, and the rated output of a
supplementary heater
Psup
is equal to the supplementary capacity for heating
sup(Tj)
.
(**) If
Cdh
is not determined by measurement then the default degradation coefficient is
Cdh
=0.9.
Fixed
For air-to-water heat pumps: Rated air flow rate,
outdoors
Sound power level, indoors/
outdoors
For water-/brine-to-water heat pumps: Rated
brine or water flow rate, outdoor heat exchanger
Emissions or nitrogen oxides
COM0028
COMMISSION REGULATION (EU) No. 813/2013
Information requirements for heat pump space heaters and heat pump combination heaters
For air-to-water heat pumps: Tj = -15°C (if TOL < -
20°C)
For air-to-water heat pumps: Tj = -15°C (if TOL < -
20°C)
Declared capacity for heating for part load at indoor temperature
20⁰C and outdoor temperature
T
j
Declared coefficient of performance or primary energy ratio for part
load at indoor temperature 20⁰C and outdoor temperature
T
j
Bivalent temperature
For air-to-water heat pumps: Operation limit
temperature
Cycling interval capacity for heating
Cycling interval efficiency
Degradation co-efficient (**)
Heating water operating limit temperature
Power consumption in modes other than active mode
Supplementary heater
Other items
ERP Information