Victorum Exhaust Air Heat Pump Installation Guide
53
Victorum Compact
Assembling the Heat Pump
Air Out
Air In
Connecting the Heat Pump
Air Out (Exhaust) Terminal
The air Out (Exhaust) terminal size is 150mm.
Air In (Extract) Terminal
The air In (Extract) terminal size is 150mm.
Spigots are supplied with the unit and these are
needed to connect a flexible duct to the top of the
unit.
Designing/Installing the Victorum
To avoid under performance of the Victorum or
increased noise the following points should be
considered when designing/installing the ducting.
•
Avoid sharp bends or transitions.
•
Swept 90° bends are preferred.
• Ensure all burrs are removed from duct ends.
• Flexible ducting should be considered above
the unit for ease of installation.
• The maximum External Static Pressure of the
ducting system should not exceed 110Pa’s
(Note; this is exclusive of the heat pump)