Description
Part No.
QTY
1
Block Wall
n/a
1
2
Concrete Floor Slab
n/a
1
3
Standard Wall Finish
n/a
1
4
Rawplug-Wall Fixing Bolt Plugs
TZ-W-00-COMP-1
2
5
Victorum Rubber Damper Bottom Circle
TZV-MOUNT-00-B
2
6
Joule Victorum
HHH-0-0000-VHP
1
7
Victorum Wall Bracket
TZ-W-00-COMP-1
1
8
Victorum Mounting Bracket Rubber Damper Top
TZV-MOUNT-00-T
1
9
Metal Stud Wall
n/a
1
10
B18.2.3.9m - Heavy Hex Flange Screw, M8 X 1.25 X 80 --22n
n/a
1
11
B18.2.3.9m - Heavy Hex Flange Screw, M8 X 1.25 X 25 --25n
n/a
1
Concrete/Block Wall Build-up
The exploded view on the opposite page details the required wall build-up to adequately support the Heat
Pump if the dwelling has Concrete or Block walls- this is the recommended wall type as it can naturally
carry the weight of the Heat Pump without reinforcement.
Use the supplied rawplugs and fixings to secure the HeatPump bracket to the wall.
Wall Build Up Detail
Internal Wall Adjoining Hallway
EXHAUST
EXHAUST 220/90 X 2M DUCT
VICTORUM
220/90
BEND
H-90°
STORE
HALLWAY
T-PIECE
220/90
220/90
125Ø
EXTRACT
VALVE
Internal Wall Adjoining Utility
VICTORUM
T-PIECE
220/90
220/90
125Ø
EXTRACT
VALVE
STORE
UTILITY
EXHAUST
VICTORUM
220/90
BEND
H-90°
Solid External Party Wall
Internal Wall Adjoining Bedroom
VICTORUM
EXHAUST 220/90 X 2M DUCT
EXTRACT 220/90 X 2M DUCT
STORE
BEDROOM