Victorum Exhaust Air Heat Pump Installation Guide
47
Victorum Compact
Product Specification
Victorum Compact EAHP Specification
Total Heating Capacity
5 Kw
Total Compressor Output
2 Kw
Max Circuit Amps (MCA)
30A
Max Fuse Amps (MFA)
32A
COP (A20, W35)
4.9
Refrigerant
R 134a
Max Flow Temperature
65°C
Heat Pump airflow range:
100-250m3/h
Trickle airflow range
50-350 m3/h
Height:
2100mm
Width:
592mm
Depth:
672mm
Shipping Weight:
125kg
Air Inlet/ Outlet Connections:
150mm
Left Side View
Front View
Plan View
Right Side View
A
B
C
A
B
C
180L
2100mm
592mm
672mm
The Victorum Compact is a pre-plumbed and wired unit containing the Victorum Exhaust Air Heat
Pump in a cased white good.
On the mechanical side, the Compact unit incorporates the hot water tank, an inline heater,
automatic air vent, DHW & heating zone valves, an automatic bypass valve and a 3-bar safety
relief valve. The inlet control group, tank cold inlet and tundish are also pre-piped.
On the Electrical side, the unit incorporates the electrical enclosure, system controller, DHW tank
Immersion heater, the DHW tank sensor and the Modbus communication cable to the Heat Pump.