www.jouleuk.co.uk | www.joule.ie
32
Victorum PrePlumb
Cyclone Cylinder Specification
Capacity
200L
250L
Cylinder Material
Stainless Steel
Duplex LDX 2101
Thermal Insulation
Polyurethane foam CFC-Free & HCFC Free
Casing
Painted Galvanised Carbon Steel DX51D
Coil Material
Stainless Steel Tube AISI 316L
Weight (empty) kg
59 kg
69 kg
Weight (full) kg
256kg
315 kg
Max. Operating Pressure
5 (bar)
Test Pressure
10 (bar)
Max. Working Temperature
90°c
Heating Elements
1. No. Incoloy
Immersion
Heat Loss
78 W
87 W
Heat up Time (mins)
31
37
Energy Efficiency Class C
C
Height (mm)
1490mm
1405mm
Diameter (mm)
530mm
600mm
Product Specification
The Victorum PrePlumb unit is a pre-plumbed and wired hot water tank, designed to be installed
alongside the Victorum Exhaust Air Heat Pump.
On the mechanical side, the PrePlumb unit incorporates the inline heater, automatic air vent, DHW &
heating zone valves, an automatic bypass valve and a 3-bar safety relief valve. The inlet control group,
tank cold inlet and tundish are also pre-piped.
On the Electrical side, the unit incorporates the electrical enclosure, system controller, DHW tank
Immersion heater and the DHW tank sensor.
Left Side View
Front View
Plan View
Right Side View
A
C
B
A
B
C
200L
1490mm
530mm
105mm
250L
1405mm
600mm
105mm