www.jouleuk.co.uk | www.joule.ie
10
Victorum EAHP Unit
Technical Specification
SAP Appx. Q Certified
Approved Results
Technical Specifications
Max Electrical Power Drawn
Watt (w)
620
Average Electrical Power Drawn
Watt (w)
300
Max Delivered Thermal Power
KW
1.7
COP (A20, W45)
4.9
Refrigerant
Type
R134a
Refrigerant Content
g
580
Dimensions & Weights
Height
mm
570
Width
mm
500
Depth
mm
500
Weight
kg
45
IP Classification
IP
x2
Flow & Return Connections
mm
15
Inch
1/2
Air Inlet
mm
150
Air Outlet
mm
150
Allowed Water Acidity Level
pH
7.5-8.0
Max Permitted Humidity Installation Space
rH
70%
Max Permissible Temperature Installation Space
°C
35
Max Flow Temperature
°C
65
Ventilation Flow Rate Whilst Heating
m³/h
100-250
Noise Level
dBa
<41
Pressure Drop
Pa
30
SAP Appendix Q - Approved Results
K 1 Wet Room
Specific
Fan Power
0.32
K 2 Wet Room
0.29
K 3 Wet Room
0.29
K 4 Wet Room
0.33
K 5 Wet Room
0.39
K 6 Wet Room
0.45