Victorum Exhaust Air Heat Pump Installation Guide
87
Setup
1. Set the working direction of the controller by pressing the joystick to right for clockwise opening
or left for counter clockwise opening (A).
2. Keep the joystick in the desired direction and connect power (B).
3. Wait 2 seconds until joystick is released (C), the correct working direction is now set
+
+
+
230V
24V
—
+
A
B
C
Victorum EAHP UFH ESBE
electronic mixing valve
Changing of target temperature
1. In order to change the target flow temperature, press the joystick to the right or to the left (A).
2. Press the joystick down to confirm new target temperature (B).
+
OK
+
—
+
A
B