Victorum Exhaust Air Heat Pump Installation Guide
67
Victorum Combi
Product Specification
Combi Pipework
A
B
Left Side View
Front View
Right Side View
DRAWN
CHK'D
APPV'D
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
NAME
SIGNATURE
DATE
JOULE ITEM NO:
DRAWING VIEWS HAVE BEEN SCALED TO FIT SHEET SIZE
REVISION:
TITLE:
EAN:
A3
Darren C.
1
SHEET 1 OF 1
VOLUME/CAPACITY:
DWG NO:
PRODUCTION BOM NO:
DESCRIPTION:
Plan View
C
DRAWN
CHK'D
APPV'D
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN MILLIMETERS
NAME
SIGNATURE
DATE
JOULE ITEM NO:
DRAWING VIEWS HAVE BEEN SCALED TO FIT SHEET SIZE
REVISION:
TITLE:
EAN:
A3
Darren C.
1
SHEET 1 OF 1
VOLUME/CAPACITY:
DWG NO:
PRODUCTION BOM NO:
DESCRIPTION:
Combi Cylinder Specification
DHW Capacity
180L
Cold Water Storage Capacity
220L
Cylinder Material
Stainless Steel Duplex LDX 2101
Thermal Insulation
Polyurethane foam CFC-Free & HCFC Free
Coil Material
Stainless Steel Tube AISI 316L
Weight (empty)
TBC kg
Weight (full)
TBC kg
Max. Operating Pressure
5 (bar)
Test Pressure
10 (bar)
Max.Working Temperature
90°c
Heating Elements
1. No. Incoloy Immersion
Heat Loss
TBC W
Energy Efficiency
Class C
Height (mm)
1850 mm
Diameter (mm)
660 mm
The Victorum Cased Combi unit is a pre-plumbed and pre-wired hot water tank, designed to be
installed alongside the Victorum Exhaust Air Heat Pump. The unit consists of a 220 litre cold water
storage tank and a 180 litre hot water tank that is designed to be pressurised.
On the mechanical side, the PrePlumb unit incorporates a 3kW inline heater, automatic air vent, DHW
& heating zone valves, an automatic bypass valve and a 3-bar safety relief valve. The inlet control
group and tundish are also pre-piped and the ball cock is installed in the cold water storage tank.
There is a Ø 180mm access hatch on the top
of the unit for service and/or maintenance work.
On the Electrical side, the unit incorporates the
electrical enclosure, system controller, DHW
tank Immersion heater and the DHW tank sensor.
A
B
C
220L
1850mm
660mm
105mm