Victorum Exhaust Air Heat Pump Installation Guide
31
Victorum EAHP Unit
Electrical Connections
The Heat Pump power cable is to be connected to a suitably sized isolator which disconnects all
poles with a contact gap of at least 3mm. The Isolator allows for isolation of the electrical power
supply for maintenance and/or repair of the Heat Pump.
•
Check all connections and the mains voltage is correct before powering On the Heat Pump
to prevent damage to the Heat Pumps electronics.’
•
If the power cable is damaged, contact Joule to have it repaired before powering On the
Heat Pump.
•
The electrical installation must be carried out by a suitably qualified electrician or under the
supervision of one. All installation work and cabling must comply to local building regulations.
Heatpump Power Cable
FUSED
The Heat Pump MUST not be powered On unless the system is
filled with water and at the recommended pressure