www.jouleuk.co.uk | www.joule.ie
18
Victorum EAHP Unit
Description
Part No.
QTY
1
Victorum Rubber Damper Bottom Circle
TZV-MOUNT00-B
2
2
Joule Victorum Vhp (Ie)
HHH-0-0000-VHP
1
3
Victorum Wall Bracket
TZ-W-00-COMP-1
1
4
400mm Timber Noggin
n/a
7
5
Concrete Floor Slab
n/a
1
6
¾” Plywood Sheet
n/a
1
7
Standard Wall Finish
n/a
1
8
Victorum Mounting Bracket Rubber Damper Top
TZV-MOUNT00-T
1
9
B18.2.3.9m - Heavy Hex Flange Screw, M8 X 1.25 X 80 --22n
n/a
2
10
B18.2.2.4m - Hex Flange Nut, M8 X 1.25 --N
n/a
2
11
Timber Stud Wall
n/a
4
Wall Build Up Detail
Timber Stud Build-up
The exploded view on the opposite page details the required wall build-up to adequately support the Heat
Pump if the dwelling has timber studs.
The wall build-up incorprates extra timber support noggins for the HeatPump bracket to be directly fixed
to. The build-up also incorporates a sheet of 3/4” plywood fixed directly to the stub before the plasteboard
is used as the standard wall finish.
Internal Wall Adjoining Hallway
EXHAUST
EXHAUST 220/90 X 2M DUCT
VICTORUM
220/90
BEND
H-90°
STORE
HALLWAY
T-PIECE
220/90
220/90
125Ø
EXTRACT
VALVE
EXHAUST
VICTORUM
220/90
BEND
H-90°
Solid External Party Wall
Internal Wall Adjoining Bedroom
VICTORUM
EXHAUST 220/90 X 2M DUCT
EXTRACT 220/90 X 2M DUCT
STORE
BEDROOM
Internal Wall Adjoining Utility
VICTORUM
T-PIECE
220/90
220/90
125Ø
EXTRACT
VALVE
STORE
UTILITY