PS200 Configuration & Operation Guide
SPEED CONTROL CONFIGURATION
Page 59
MOTOR DATA
The motor data will allow the PumpSmart drive to characterize the
motor during its first start-up. During characterization,
PumpSmart will automatically magnetize the motor windings for
20 - 60 seconds to develop a mathematical model of the motor.
Entry of the following parameters is all that is required.
NOTE - If the motor is changed in the future, this data must be re-
entered and a new characterization will be performed.
NOTE - The information required for this section can be found on
the motor nameplate.
11.04 MOTOR NOM VOLTAGE
KEY SEQUENCE
[From parameter group: 12 START/STOP]
OR
Scroll to parameter 11.04
“MOTOR NOM VOLTAGE”
ENTER
Press to enter the
parameter setting mode
OR
OR
Use a combination of the
arrow keys to scroll to the
nameplate motor voltage.
Enter the value for
motor voltage and
frequency. Available
selections are
208 VAC - 60 Hz
220 VAC - 50 Hz
220 VAC - 60 Hz
230 VAC - 60 Hz
380 VAC - 50 Hz
415 VAC - 50 Hz
460 VAC - 60 Hz
(default)
575 VAC - 60 Hz
OTHER
Selecting OTHER will require
entry in parameters 11.06
MOTOR NOM FREQ and
11.12 OTHER MOTOR VOLT.
ENTER
Press to complete the
entry
11.05 MOTOR NOM CURRENT
KEY SEQUENCE
[From parameter group: 11.04 MOTOR
NOM VOLTAGE]
OR
Scroll to parameter 11.05
“MOTOR NOM CURRENT”
ENTER
Press to enter the
parameter setting mode
OR
OR
Use a combination of the
arrow keys to scroll to the
nameplate motor current.
Enter the actual full load
amps (FLA) of the
motor here. Refer to the
motor nameplate for the
correct value.
ENTER
Press to complete the
entry
ACT
PAR
FUNC
DRIVE
ENTER
1 L
Æ
0 R P M 0
1 1 S T A R T - U P D A T A
4 M O T O R N O M V O L T A G E
460
ACT
PAR
FUNC
DRIVE
ENTER
1 L
Æ
0 R P M 0
1 1 S T A R T - U P D A T A
5 M O T O R N O M C U R R E N T
25
Summary of Contents for PumpSmart PS200
Page 1: ... PUMPSMART CONTROL SOLUTIONS PS200 Version 4 0 Configuration Operation Guide ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 26: ......
Page 72: ......
Page 105: ......
Page 119: ......
Page 146: ...PS200 Configuration Operation Guide APPENDIX A 3 PARAMETER LISTING Page 143 ...
Page 147: ......
Page 158: ......