PS200 Configuration & Operation Guide
SINGLE PUMP PROCESS
Page 12
ID MAGN REQ
This warning is normal, proceed on to the step
INDENTIFICATION RUN
IDENTIFICATION RUN
PumpSmart uses specific motor detail to create a mathematical
motor model. This model enables more accurate motor control
and is created with the motor data you have just entered and by
magnetizing the motor for 20 to 60 seconds at zero speed. This is
called a First Start ID Run.
Once all the motor data has been entered, the following warning
will be displayed:
ID MAGN REQ
This warning indicates that a First Start ID Run is required before
the pump may be operated. Now is a good time to perform this
run.
With the motor connected to the drive and the keypad in Local (L)
mode, press the START button. FOLLOW ALL STANDARD SAFETY
PRACTICES FOR STARTING MACHINERY.
NOTE
ALLOW THE FIRST START ID RUN TO COMPLETE BEFORE
STOPPING/RESETTING THE DRIVE. Although the motor may not
appear to respond to the start command, it has. A warning
message “ID MAGN” will be displayed during the ID. Once the ID
run is complete, the message "ID DONE" will be displayed.
NOTE - If the motor is changed in the future, a First Start ID Run
must be performed again to maintain the accuracy of the
PumpSmart control.
Once the First Start ID Run has been completed, the following
message will appear:
ID DONE
Once this appears, proceed on to the next step DRIVE OPERATION
LIMITS.
E-Stop/Permissive
The PS200 will not operate unless
the E-Stop/Permissive switch [DI1L]
is closed. This includes performing
the First Start ID Run. If not closed
a warning message will appear on
the keypad display:
R U N D I S A B L E D
See Appendix A-4, Instrument
Wiring, for details on wiring this
switch.
NOTE:
The E-Stop/Permissive switch can not
be defeated through parameter
setting. If your application does not
use an E-Stop / Permissive switch, DI1L
can be bypassed physically inside the
PumpSmart unit. Refer to Appendix A-
4, Instrument Wiring, for details.
Summary of Contents for PumpSmart PS200
Page 1: ... PUMPSMART CONTROL SOLUTIONS PS200 Version 4 0 Configuration Operation Guide ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 26: ......
Page 72: ......
Page 105: ......
Page 119: ......
Page 146: ...PS200 Configuration Operation Guide APPENDIX A 3 PARAMETER LISTING Page 143 ...
Page 147: ......
Page 158: ......