S R A / S F X 2 1 0 0 S E R I E S S A T E L L I T E R E C E I V E R
59
Menu Item
Description
Edit IGMP
<interface>
Selecting this button will enter the IGMP Edit page, as shown in
Figure 4-17, for the selected Ethernet network interface.
Restore
<interface>
Defaults
Selecting this button will enter the IGMP Edit page, but with factory
default values inserted into the edit fields automatically. You may
then wish to edit these values, in the same manner used when the
Edit IGMP buttons were pressed.
The following default values are inserted:
IGMP Disabled (pass all multicast packets out the network interface)
Robustness Variable = 2.
Query Interval = 125 seconds.
Query Response Interval = 10 seconds.
Last Member Query Interval = 1 seconds.
Last Member Query Count = 2.
Starting Query Interval = 31 seconds.
Starting Query Count = 2.
The individual IGMP variables displayed are explained with the IGMP Edit page. When the
Edit menu item is selected, the IGMP Edit page will be displayed, as shown by the sample
page in Figure 4-17. Each edit field is described after the figure.
Figure 4-17 IGMP Edit Page