S R A / S F X 2 1 0 0 S E R I E S S A T E L L I T E R E C E I V E R
171
Figure F-5 Conditional Access Configuration Edit Page
The following fields can be edited on the Conditional Access Configuration Edit page:
Edit Field
Description
Program #
Enter the valid program number within the PAT as a decimal or
hexadecimal number. This will be used to index into the PAT to
determine the PID number of the PMT.
PAT PID #
For special DVB systems and for added flexibility, you may need
to enter a PID number for the PAT that is something other than
PID 0. This field is provided for that purpose and if left
untouched, will default to 0.
Front Panel LED Indications
When the DVB CAS Option is installed, certain indicators on the front panel will behave
differently and provide additional status information, as follows:
OPTIONS
Purpose: provides status of the CAS operation.
Colour: off/green, where:
Solid Green – CAS option is installed.
Flashing Off/Green – PAT/PMT tables are being received.
Off – the CAS option is not installed.
NOTE:
Please note the
warnings that
are printed on
the Conditional
Access
Configuration
Edit Page.