Chapter 2: Hardware Installation
05
# 6-32 x 6mm Flat Head screws
4
06
M5 cage nuts
4
07
Filler plates behind forearm handles
4
Table 2-1: Rackmount Kit Components
Step 2.
Determine the position where the subsystem is going to be
installed on the rack. Place the bracket into the rack and
slide the brackets to adjust them to the length between
rack posts as shown below.
Figure 2-3: Adjusting Rail Length and Attaching Screws
Step 3.
Secure the left-side and right-side rails to the rack with two
(2) M5 flathead screws on the front and the rear rack
posts. (See the figure above)
Step 4.
Attach two (2) M5 cage nuts to both sides of the front rack
posts. There are four rack post holes between the two
securing M5 flathead screws. The two (2) cage nuts
should be attached to the first and the last holes. (See the
figure below)
Figure 2-4: Attaching Cage Nuts