Appendix A: Specifications
Operating: -10 to +70ºC
Storage: -30 to +70ºC
S12F-G1433
Operating: -10 to +60ºC
Storage: -20 to +70ºC
A.5 RAID
Management
Specifications
Configuration
•
Text-based firmware-embedded utility
over RS-232C through the included serial
cable; Y-cable for the dual-controller
model.
•
Telnet via an established network
connection
•
LCD
keypad
panel
•
The SANWatch management suite using
in-band or Ethernet connection
Performance
Monitoring
Yes; http and web(SSL) access to an
embedded RAIDWatch manager
Remote Control
and Monitoring
Yes
Event
Broadcast/Alert
Yes, via SANWatch management suite
Event Notification
Yes, via SANWatch management suite
Hardware
Connection
In-band over Fibre, out-of-band via Ethernet
or RS-232C
Configuration on
Disk
Configuration data stored on disks so that
logical drive configurations exist after
controller replacement; basic settings, e.g.,
channel mode settings, are stored on
NVRAM.
Failure Indicator
Faults are indicated via audible alarm, module
LED indicators, LCD panel, SANWatch
management suite, or terminal emulation.
A.6
Fault Tolerance Management
Specifications
Drive S.M.A.R.T Support
Yes, with user-configurable
detect-only, clone and
replace, and perpetual clone
functions.
Battery Back-up Option
Yes, life expectancy and
charge level aware
Sensors and module presence
detection through an I
2
C serial bus
Yes
Automatic Drive Failure Detection
Yes
A-5