EonStor S12F-R1432/G1433 Installation and Hardware Reference Manual
In accordance with international transportation regulations, the BBU
is only charged to between 35% and 45% of its total capacity when
shipped. After powering on the subsystem, the BBU will
automatically start charging its battery cells. It usually requires
approximately twelve (12) hours for the battery to be fully charged.
If the battery is not fully charged after twelve (12) hours, a problem
might have occurred with the BBU and you should contact your
subsystem vendor for a replacement. If BBU charger has overheated
and forced the charging process to halt many times during the
charging process, re-installing the BBU may sometimes correct the
fault. If the overheating conditions occurred during the process,
charge time must extend the expected twelve hours.
While the battery is being charged, the LED on the BBU will flash
slowly. You can also check the status of the battery module via
SANWatch or the firmware.
1.3.6 PSUs
Figure 1-18: PSU Module of S12F-R1432
Figure 1-19: PSU Module of S12F-G1433
1-14