7 | Warning and error messages
INFICON
88 / 140
UL3000-Fab-Operating-instructions-iina73en1-08-(1910)
Type
Notification
Possible sources of
error
Remedy
W104
One EEPROM parameter
has been initialized
A new parameter was
introduced by a
software update
• Confirm the warning message
• Check that the message does not appear
when you restart the device
• Check whether the factory settings
correspond with the new parameter of
your application
The EEPROM on the
VI-Board is defective
• Confirm the warning message
• Check if the message occurs each time
when you restart the device
• Contact customer service
W106
Several EEPROM
parameters have been
initialized
A software update
introduced new
parameters
• Confirm the warning message
• Check that the message does not appear
when you restart the device
• Check whether the factory settings
comply with the new parameters of your
application
The EEPROM on the
VI-Board was replaced
• Confirm the warning message
• Check that the message does not appear
when you restart the device
• Check whether the factory settings
comply with the new parameters of your
application
The EEPROM on the
VI-Board is defective
• Confirm the warning message
• Check if the message occurs each time
when you restart the device
• Contact customer service
E107
Internal IIC communication
error
Internal IIC
communication error
• Contact customer service
E108
Internal IIC2 communication
error
Internal IIC2
communication error
• Contact customer service
Summary of Contents for ULTRATEST UL3000 Fab
Page 2: ...INFICON GmbH Bonner Strasse 498 50968 Cologne Germany ...
Page 133: ...INFICON Appendix 11 UL3000 Fab Operating instructions iina73en1 08 1910 133 140 ...
Page 134: ...11 Appendix INFICON 134 140 UL3000 Fab Operating instructions iina73en1 08 1910 ...
Page 138: ...Index INFICON 138 140 UL3000 Fab Operating instructions iina73en1 08 1910 ...
Page 139: ......
Page 140: ......