143
IE
3.22 TECHNICAL DATA.
- Flue temperature values refer to an air inlet temperature of 15°C and
delivery temperature of 50°C.
- The data relevant to domestic hot water performance refer to a dynamic
inlet pressure of 2 bar and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet considering that to obtain the data
declared mixing with cold water is necessary.
- The max. sound level emitted during boiler operation is < 55dBA. The
sound level value is referred to semianechoic chamber tests with boiler
operating at max. heat output, with extension of fume exhaust system
according to product standards.
- * Specific capacity “D”: domestic hot water flow rate corresponding to an
average increase of 30K, which the boiler can supply in two successive
withdrawals.
Domestic hot water nominal heat input
kW (kcal/h)
26,7 (22933)
Central heating nominal heat input
kW (kcal/h)
24,1 (20747)
Minimum heat input
kW (kcal/h)
3,2 (2719)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
26,0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23,6 (20296)
Minimum heat output (useful)
kW (kcal/h)
3,0 (2580)
Efficiency 80/60 Nom./Min.
%
97,8 / 94,9
Efficiency 50/30 Nom./Min.
%
106,7 / 103,0
Efficiency 40/30 Nom./Min.
%
108,1 / 107,1
Heat loss at casing with burner On/Off (80-60°C)
%
0,41 / 0,50
Heat loss at flue with burner On/Off (80-60°C)
%
0,02 / 2,00
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature Pos 1
°C
20 - 85
Adjustable central heating temperature Pos 2
°C
20 - 50
Total volume system central heating expansion vessel
l
5,7
Expansion vessel factory-set pressure
bar
1
Water content in generator
l
3,4
Total head available with 1000 l/h flow rate
kPa (m H
2
O)
18,63 (1,90)
Hot water production useful heat output
kW (kcal/h)
26,0 (22360)
Domestic hot water adjustable temperature
°C
30 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
8,75
Min. pressure (dynamic) domestic hot water circuit
bar
0,3
Domestic hot water circuit max. working pressure
bar
10
*Specific capacity “D” according to EN 6625
l/min
11,8
Drawing capacity in continuous duty (∆T 30°C)
l/min
12,9
Weight of full boiler
kg
42,4
Weight of empty boiler
kg
39,0
Power supply connection
V/Hz
230/50
Power input
A
0,61
Installed electric power
W
135
Pump consumption
W
83,5
Fan consumption
W
10
Equipment electrical system protection
-
IPX4D
NO
X
class
-
5
Weighted NO
X
mg/kWh
39,0
Weighted CO
mg/kWh
17,2
Type of appliance
C13 / C23 / C33 / C43 / C53 / C63 / C83 / B23p / B33
Category
II2H3P