The fieldbus command channel (module 11)
Module 11, command 22dec (16hex) – reset telegram error counter of a slave
125
6.18.3
Example: reset telegram error counter of slave 7(A) on AS-i
master 2
4804
Request from fieldbus master to device
Word no.
Value [hex.]
Meaning
1 8716
(slave no.
7
)
+ (master no.
2 * 64
)
+ (32, if B slave)
= 135
dec
=
87
hex
16 = command 22
2 0000
not
used
Response from device to fieldbus master
Word no.
Value [hex.]
Meaning
1 8716
copy of the request
command processed, no error occurred
2 0000
not
used