Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
2BA00013 Service processor
reports bad NVRAM
CRC.
1. If problem persists, replace battery.
2. Replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00014 Service processor
reports bad service
processor firmware.
Attempt to reload the service processor firmware. Use the service terminal
Licensed Internal Code Maintenance Menu, Firmware LIC Menu, System Planar
/ Service Processor Menu options.
If the reload fails, replace the service processor card (E10/E20 only) or the I/O
planar (F10/F20 only, which contains the SP function).
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00017 Service processor
reports bad or low
battery.
1. Replace the battery.
2. Replace the Service Processor Card (E10/E20 only).
3. Replace I/O Planar (E10/E20 and F10/F20).
The F10/F20 I/O planar includes the service processor.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00018 EPOW test failure.
1. Replace the service processor.
2. Replace the I/O Planar (E10/E20 and F10/F20).
The F10/F20 I/O planar includes the service processor.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00019 IRQ13 test failure.
1. Replace the I/O Planar.
2. Replace the Service Processor Card (E10/E20 only).
The F10/F20 I/O planar includes the service processor.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00024 Service processor
reports bad Power
Controller firmware.
Attempt to reload the service processor firmware. Use the service terminal
Licensed Internal Code Maintenance Menu, Firmware LIC Menu, System Planar
/ Service Processor Menu options.
If the reload fails, replace the service processor card (E10/E20 only) or the I/O
planar (F10/F20 only, which contains the SP function).
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00040 Service processor
reports Service
Processor EEPROM
module not present.
Attempt to reload the service processor firmware. Use the service terminal
Licensed Internal Code Maintenance Menu, Firmware LIC Menu, System Planar
/ Service Processor Menu options.
v
Replace the Service Processor Card (E10/E20 only).
v
Replace I/O Planar (F10/F20 only).
The F10/F20 I/O planar includes the service processor.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
2BA00041 Service processor
VPD is corrupted.
Refer to the actions in error code 2BA00040.
Codes
82
VOLUME 3, ESS Service Guide
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...