Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
25A80xxx NVRAM problems
NVRAM problem resolution:
1. Errors reported against NVRAM can be caused by low I/O Planar Battery
voltage and (more rarely) cluster bay power problems. With the exception of
the 25A80000 error, these errors are warnings that the NVRAM data content
had to be reestablished and do not require any FRU replacement unless the
error is persistent.
2. If the error is persistent, replace the I/O planar battery.
3. If the error is persistent after battery replacement, or the error code is
25A80000, replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
25A80000 Initialization failed,
device test failed.
Refer to the actions in error code 25A80xxx.
25A80001 Init-NVRAM invoked,
ALL of NVRAM
initialized.
Refer to the actions in error code 25A80xxx.
25A80002 Init-NVRAM invoked,
some data partitions
may have been
preserved.
Refer to the actions in error code 25A80xxx.
25A80011 Data corruption
detected, all of
NVRAM initialized.
Refer to the actions in error code 25A80xxx.
25A80012 Data corruption
detected, some data
partitions may have
been preserved.
Refer to the actions in error code 25A80xxx.
25A80100 NVRAM data
validation check failed.
1. Power off and on the cluster bay and retry the operation. Connect the
service terminal to the working cluster bay and use the Alternate Cluster
Repair Menu options to quiesce, power off, power on and resume the failing
cluster bay.
2. Replace any FRUs in the actions in error code 25A80xxx.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
25A80201 Unable to expand
target partition while
saving configuration
variable.
Refer to the actions in error code 25A80xxx.
25A80202 Unable to expand
target partition while
writing error log entry.
Refer to Action under error code 25A80xxx.
25A80203 Unable to expand
target partition while
writing VPD data.
Refer to Action under error code 25A80xxx.
25A80210 Setenv/$Setenv
parameter error -
name contains a null
character.
Refer to Action under error code 25A80xxx.
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
77
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...