v
Use the progress code/indicator description to identify the failing FRU(s)
v
Some progress codes will include a physical location code on the second line of the cluster
display panel. That may be the failing FRU.
v
Call the next level of support.
Configuration Program Progress Indicators
Find the code and description below then read note 135.
0005
IML retry threshold count reached
0500
Querying Standard I/O slot.
0501
Querying card in Slot 1.
0502
Querying card in Slot 2.
0503
Querying card in Slot 3.
0504
Querying card in Slot 4.
0505
Querying card in Slot 5.
0506
Querying card in Slot 6.
0507
Querying card in Slot 7.
0508
Querying card in Slot 8.
0510
Starting device configuration.
0511
Device configuration completed.
0512
Restoring device configuration files from media.
0513
Restoring basic operating system installation files from media.
0517
The /root and /usr file systems are being mounted.
0520
Bus configuration running.
0521
/etc/init invoked cfgmgr with invalid options; /etc/inithas been corrupted or incorrectly modified
(irrecoverable error).
0522
The configuration manager has been invoked with conflicting options (irrecoverable error).
0523
The configuration manager is unable to access the ODM database (irrecoverable error).
0524
The configuration manager is unable to access the config.rules object in the ODM database
(irrecoverable error).
0525
The configuration manager is unable to get data from a customized device object in the ODM
database (irrecoverable error).
0526
The configuration manager is unable to get data from a customized device driver object in the
ODM database ( irrecoverable error).
0527
The configuration manager was invoked with the phase 1 flag; running phase 1 at this point is not
permitted (irrecoverable error).
0528
The configuration manager cannot find sequence rule, or no program name was specified in the
ODM database (irrecoverable error).
0529
The configuration manager is unable to update ODM data (irrecoverable error).
0530
The program savebase returned an error.
0531
The configuration manager is unable to access the PdAt object class (irrecoverable error).
0532
There is not enough memory to continue (malloc failure); irrecoverable error.
0533
The configuration manager could not find a configure method for a device.
0534
The configuration manager is unable to acquire database lock (irrecoverable error).
0535
HIPPI diagnostics interface driver being configured.
0536
The configuration manager encountered more than one sequence rule specified in the same
phase (irrecoverable error).
0537
The configuration manager encountered an error when invoking the program in the sequence rule.
0538
The configuration manager is going to invoke a configuration method. See 135.
0539
The configuration method has terminated, and control has returned to the configuration manager.
0551
IPL vary-on is running.
0552
IPL vary-on failed.
0553
IPL phase 1 is complete.
0554
The boot device could not be opened or read, or unable to define NFS swap device during
network boot. If this hangs, go to
″
MAP 4020: SCSI Hard Drive Build
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Failing Function Codes
136
VOLUME 3, ESS Service Guide
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...