D
= Diskette Drive (D1) or Disk Drive Module (Dxx)...where
″
xx
″
= 01...16
E
= Ethernet
F
= Fan or sensor (Fxx), where
″
x
″
= Fan 01...99
G
= Rack Power Control Card, Remote Power Control Card (Gx), where
″
x
″
= 1...2
H
= Ultra SCSI Host Card (Hx)...where
″
x
″
= Ultra SCSI Host Card slot
I
= I/O Planar Card slot (Ix), where
″
x
″
= 1...9
J
= Connector (Jxx), where
″
xx
″
= 1...99, A...Z
K
= SSA Device Card Slot (Kx), where
″
x
″
= 1...9
L
= LCD Operator Panel (L1)
M
= Memory Card (Mx), where
″
xx
″
= 1...2
N
= Connector (Nxx), where
″
xx
″
= 01...99
O
= unused
P
= Planar or Backplane (Px), where
″
x
″
= 1...9
Q
= Power / Cooling for Storage Cage, in between the Storage Cage (Qx), where
″
x
″
= 1...2
R
= Rack (Rx), where
″
x
″
= Rack 1...3
S
= Slot Port (Sx), where
″
x
″
= Serial Port 1...3
T
= Cluster Bay (Tx), where
″
x
″
= 1...2
U
= Storage Cage / Electronics Cage (Ux), where
″
x
″
= 1...4
V
= Voltage (Power Supply or Battery) (Vxx), where
″
xx
″
= 01...99
W
= DDM bay (Wx), where
″
x
″
= 1...6
X
= Extra-Function Card (i.e. Service Processor) (Xx), where
″
x
″
= 1...9
Y
= SSA 7133 Drawer (Yx), where
″
x
″
= 0...8
Z
= SCSI Card, ESCON Card, Fibre Channel Card (Zx) connector, where
″
x
″
= 1...2
Locating a DDM Bay or SSA DASD Model 020 or 040 Drawer in a 2105
Rack
Use the following procedure to locate a DDM bay or SSA DASD Model 020 or 040 drawer in a 2105
Model Exx/Fxx, 2105 Expansion Enclosure, or 2105 Model 100 rack.
Note: If you already know where the rack is located, its model number, and the configuration of its DDM
bays and SSA DASD Model 020 or 040 drawers, skip this procedure and go to Table 1 on page 8.
1. Record the location code of the DDM bay or SSA DASD Model 020 or 040 drawer you are
locating. The first two characters of the DDM bay or SSA DASD Model 020 or 040 drawer
location code (R#-) indicate what rack they are mounted in. Reference Figure 1 on page 7 and
Figure 2 on page 7 the two possible subsystem configurations.
2. Locate the rack number (R#-) in the following list and go to the page or step indicated:
v
R1- (2105 Model Exx or Fxx), go to “Rack Location Codes for DDM Bays in a 2105 Model
Exx/Fxx” on page 8
v
R2- (2105 Expansion Enclosure), go to “Rack Location Codes for DDM Bays in a 2105
Expansion Enclosure” on page 9
v
R2- (2105 Model 100), go to “Rack Location Codes for SSA DASD Model 020 or 040
Drawers in a 2105 Model 100” on page 11
Locations
6
VOLUME 3, ESS Service Guide
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...