Table 13. Failing Function Code Table (continued)
Failing
Function
Code
FRU and Notes
804
CD-ROM Drive
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
80C
SSA device card problem. Display problems needing repair or call next level of support.
811
Processor complex being identified. Call next level of support.
812, 814
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
815
CPU Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
816, 817,
821, 823,
824, 826,
827, 828,
831,868,
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
887
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
935
Diskette Drive
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
946
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
B88
I/O Planar
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
D01
CPU Card
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
D50
SCSI Signal Cable, SCSI termination on SCSI Hard Drive
Note:
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the Enterprise Storage Server Service
Guide, Volume 1
Diagnostic Numbers and Codes
Operator Panel Display Numbers
This section contains a list of the various numbers and characters that may be displayed on the cluster
bay operator panel display. The numbers and characters are divided into two categories:
1. Information about the configuration program status, see “Configuration Program Progress Indicators”
on page 136
2. Information messages that follow a blinking 888, see “Diagnostic Load Progress Indicators” on
page 138
Note: A code displayed on the cluster display panel during cluster power on can be considered hung after
five minutes. Do the following steps as appropriate:
Failing Function Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
135
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...