Table 7. Memory DIMM PD bits
PD value
Size
Clock Cycle (nsecs)
Parity/ECC
38
128 MB
10
ECC
68
256 MB
10
ECC
Note: Memory modules must be installed in pairs.
Bus SRN to FRU Reference Table
These tables are used to locate defective FRUs within the I/O Planar PCI and ISA buses. These tables
indicate which devices should be tested for each SRN. For this procedure, if possible, diagnostics are run
on the I/O Planar bus devices with all adapters removed from the failing bus. If a failure is detected on this
system with all adapters removed from the failing bus, the I/O Planar is the isolated FRU. If a failure is not
detected, the adapters are added back one at a time, to their original slot location, and the configuration is
tested until a failure is detected. The failure is then isolated to the failing FRU.
If a failure has not been detected and all the FRUs have been tested call your technical service support
person for assistance.
Go to the correct table for your product:
v
2105 Model E10/E20, go to Table 8.
v
2105 Model F10/F20, go to Table 9 on page 100.
Table 8. Bus SRN to FRU Reference Table (Models E10/E20 Only)
SRN
Bus Identification
Possible Failing Device and AIX Location
Code
Associated FRU
9CC-100
PCI Bus 00
Internal SCSI port 1 (10-60)
I/O Planar. (See notes
on 72)
Internal Ethernet port (10-80)
I/O Planar. (See notes
on 72)
Device installed in I/O Slot K3 (10-68 to 10-6F)
SSA Device Card
Device installed in I/O Slot I4 (10-70 to 10-77)
I/O Attachment Card
Device installed in I/O Slot I5 (10–78 to 10–7F)
NVS Card
9CC-101
PCI Bus 01
Device installed in I/O Slot K1 (20-58 to 20-5F)
SSA Device Card
Device installed in I/O Slot K2 (20-60 to 20-67)
SSA Device Card
9CC-102
PCI Bus 02
Internal/External SCSI port 2 (30-58)
I/O Planar (See notes
on 72)
Device installed in I/O Slot I6 (30-60 to 30-67)
NVS Card
Device installed in I/O Slot I7 (30-68 to 30-6F)
I/O Attachment Card
Device installed in I/O Slot 8P (30-70 to 30-77)
I/O Planar
Device installed in I/O Slot K9 (30-78 to 30-7F)
SSA Device Card
651-730
ISA Bus
Diskette Drive port/device (01-D1-00-00)
I/O Planar
Parallel port/device (01-R1)
I/O Planar
Serial ports (1-3)/device (01-S1 to 01-S3)
I/O Planar
Mouse port/device (01-K1-01-00)
I/O Planar
Key-Planar port/device (01-K1-00-00)
I/O Planar
Device installed in I/O Slot 8I (01-01 or 01-02)
I/O Planar
Device installed in I/O Slot 9I (01-01 or 01-02)
I/O Planar
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
99
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...