Table 6. Firmware Error Codes. (continued)
Error
Code
Description
Action/ Possible Failing FRU
25A80211 Setenv/$Setenv
parameter error - value
contains a null
character.
Refer to Action under error code 25A80xxx.
25AA0xxx EEPROM problems.
Replace the I/O Planar.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
25AA0000 Unable to unlock
EEPROM.
Refer to Action under error code 25AA0xxx.
25AA0001 Read-Recv error.
Refer to Action under error code 25AA0xxx.
25AA0002 Read-Trans error.
Refer to Action under error code 25AA0xxx.
25AA0003 Write-enable error.
Refer to Action under error code 25AA0xxx.
25AA0004 Write-recv error.
Refer to Action under error code 25AA0xxx.
25AA0005 Write-disable error.
Refer to Action under error code 25AA0xxx.
25AA0006 Write-Trans error.
Refer to Action under error code 25AA0xxx.
25AA0007 Unable to lock
EEPROM.
Refer to Action under error code 25AA0xxx.
25B00001 No memory modules
detected in either
memory card 1 or 2.
1. Reseat any installed memory card(s) and retry.
2. Reseat any installed memory modules on the installed memory cards.
3. Replace Memory Card(s).
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
25Cyyxxx Memory Card
problems.
See “Memory PD Bits” on page 98 for definition of
″
yy
″
.
Use the location code obtained from the SMS Error Log utility (described in
″
MAP 4400: Cluster SMS Error Logs
″
in chapter 3 of the Enterprise Storage
Server Service Guide, Volume 1) to identify which memory module (or memory
module pair) the error is reported against.
25Cyy001 Incorrect memory
module type is
present.
One or more memory modules are the wrong type and do not match the
remaining memory modules. Remove the incorrect memory modules and replace
them with the correct memory module type.
There might be two memory module related memory errors reported to indicate
a memory module pair. One of the two memory modules could be in good
condition.
See “Memory PD Bits” on page 98 for definition of
″
yy
″
.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
25Cyy002 Memory module fails
memory test.
1. Replace memory module.
2. Replace memory card.
3. Replace the System Planar.
See “Memory PD Bits” on page 98 for definition of
″
yy
″
.
Note: Go to
″
MAP 4700: Cluster Bay FRU Replacement
″
in chapter 3 of the
Enterprise Storage Server Service Guide, Volume 1.
Codes
78
VOLUME 3, ESS Service Guide
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...