Table 12. Service Request Numbers (continued)
Service
Request
Number
SRN
Src.
Failing
Function
Codes
Description and Action
651-160
D
2E0
Description: I/O planar sensor indicates a fan is turning too slowly.
Note: Go to
″
MAP 4740: Fan Check Detected by I/O Planar
″
in chapter 3
of the Enterprise Storage Server Service Guide, Volume 1.
651-161
D
152 2E2
Description: Sensor indicates a voltage is outside the normal range.
651-162
Description: See SRN 651-152
651-170
D
Description: Sensor status not available.
Action: Contact your next level of support.
651-171
D
Description: Sensor status not available
Action: Contact your next level of support.
651-600
G
Description: Uncorrectable memory or unsupported memory.
Action: Examine the memory modules and determine if they are supported
types. If the modules are supported, then replace the appropriate memory
module(s).
651-601
G
Description: Missing or bad memory
Action: If the installed memory matches the reported memory size, then
replace the memory: otherwise, add the missing memory.
651-603
G
2C6 2C7
Description: Bad or missing memory
651-605
G
2C6
Description: Failed memory module
Action: The most probable failure is the memory module paired with the
memory module identified by the location code.
651-608
G
D01
Description: Bad L2 Cache
651-609
G
D01
Description: Missing L2 Cache
651-610
G
210
Description: CPU internal error
651-611
G
210
Description: CPU internal cache error
651-612
G
D01
Description: L2 Cache parity or multi-bit ECC error
651-613
G
D01
Description: L2 cache ECC single-bit error
651-614
G
214
Description: Time-out error waiting for memory controller
651-615
G
292
Description: Time-out error waiting for I/O
651-619
G
Description: Problem log analysis indicates an error detected by the CPU.
The error log indicates the following physical FRU location(s) as the
probable cause(s).
Action: Use the physical location codes to replace the FRUs that are
identified on the problem detail screen.
651-621 and
651-623
G
2C6
Description: Correctable error threshold exceeded
651-624
G
214
Description: Memory controller internal error
651-625
G
214
Description: Memory Address (Bad address going to memory)
651-626
G
214
Description: Memory Data error (Bad data going to memory)
651-627
G
214
Description: Memory time-out error
651-628
G
210
Description: Processor time-out error
Codes
Error Messages, Diagnostic Codes, and Service Reports, CHAPTER 9
117
Summary of Contents for E10
Page 2: ......
Page 68: ...52 VOLUME 3 ESS Service Guide...
Page 192: ...2105 Exception Symptom Codes 176 VOLUME 3 ESS Service Guide...
Page 198: ...Translation 182 VOLUME 3 ESS Service Guide...
Page 256: ...CPI Diagnostic Progress Code Stop 240 VOLUME 3 ESS Service Guide...
Page 257: ...CPI Diagnostic Progress Code Stop Appendix C Isolating a CPI Diagnostic Progress Code Stop 241...
Page 258: ...CPI Diagnostic Progress Code Stop 242 VOLUME 3 ESS Service Guide...
Page 259: ...Glossary of Terms and Abbreviations Copyright IBM Corp 1999 2000 243...
Page 277: ......
Page 279: ...Spine information Enterprise Storage Server VOLUME 3 ESS Service Guide...