CA BER
NCP CA BER Type 10
CA BER Type 10 - Summary
Table 11-58 (Page 1 of 5). CA BER Type 10 Summary
BER
ID
Abend
Code
(NCP)
Event Description
Recovery
or PGM
Action
ALERT
ALARM
10
0915
CADS: Invalid ESC address used (EP or NEO are
the CA owner)
– Mismatch between ESC addresses range
defined in NCP/PEP sysgen and in MOSS CDF
for involved CA.
– Program error (for example, possible overwrite
of control blocks where ESC values are kept) if
found in normal operations
BCCA: ESC addresses not allowed on this type of
CA.
NCP re-IPL
NO
NO
14
0910
Address exception (AIO) (X'76' bit 0.0 or 1.0 ON)
NCP re-IPL
NO
NO
16
0911
Storage protect (AIO) (X'76' bit 0.1 or 1.1 ON)
NCP re-IPL
NO
NO
18
0912
Invalid CA selection in control program (attempt to
select a non-installed CA). Control program issuing an
output X'07' with either bit 0.2 or 0.3 set and bits 0.4,
0.6 indicating select bits for a CA that is not installed.
NCP re-IPL
NO
NO
1B
0913
Invalid IOH/IOHI input to CA (for example input to reg-
ister which cannot be read) X'7E' bit 0.5 ON
NCP re-IPL
NO
NO
1C
0914
Output sequence issued in error to CA X'0D' bit 1.0 ON
NCP re-IPL
NO
NO
1E
0913
Invalid IOH/IOHI output to CA output X'0D', X'0E', or
X'0F'
NCP re-IPL
NO
NO
1F
0913
Invalid IOH/IOHI output to CA (hardware detected)
X'7E' bit 0.5 ON
NCP re-IPL
NO
NO
34
091F
Level 3 IPL configuration check
Stacked status cleared by initial select for the 1st
time, or transfer of final status but not on the
IPLing CA. built for the non-IPLing CA
PRI built for the IPLing CA
NCP re-IPL
NO
NO
35
0
ESC address (from host) not within range (PEP on
level 3 interrupt)
Mismatch between ESC addresses range defined in
NCP/PEP sysgen and in MOSS CDF for involved CA.
NO
NO
80
0
Autoselection error: IOH IN X'0F' failed (X'09' and X'0A'
contain 'FEFE')
Retry cmd
in X'0F'
80
0920
Autoselection error (limit threshold)
X'76' bit 0.4 ON for IOC1 time out, or
X'76' bits 0.0 to 0.3 contain '0010'.
NCP re-IPL
NO
NO
80
0
Autoselection error (limit threshold)
X'76' bit 0.4 ON for IOC1 time out, or
X'76' bits 0.0 to 0.3 contain '0101'.
CA down
50
50
80
0920
Autoselection error (limit threshold)
X'76' bit 0.4 ON for IOC1 time out, or
X'76' bits 0.0 to 0.3 contain '0101'.
NCP re-IPL
NO
NO
11-164
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Summary of Contents for 3745 Series
Page 2: ......
Page 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Page 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Page 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Page 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Page 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 708: ......
Page 711: ......
Page 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...