MOSS BER (ID 06)
Table 11-27 (Page 2 of 5). MOSS BER Type 01 ID 06 Field Details
Field Name
Bit Pattern
or
Hex Value
Meaning
Abend code
xxxx xxxx
xxxx xxxx
IPL abend code
LA byte 1
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
. . . .
. . . .
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
32 blocks (1 per CSP) of 4 bytes, displayed
as 8 hexadecimal characters
LPTSS found present in CDF
TRA found present in the CDF
Adapter power ON
Scanner/TRA is presently the scanner selected
TIC1 found present in CDF
TIC2 found present in CDF
LA under control of the CP
Scanner successfully IMLed
LA byte 2
x . . .
. . . .
. x . .
. . . .
. . x .
. . . .
. . . x
xxx .
. . . .
. . . x
Automatic re-IML has failed, or scanner went down
twice in the minimum time range, or CSP could not
be IMLed at general IPL.
CMD engaged with scanner failed with a level 1
interrupt on MOSS: interrupt handler failed
in trying a get error status register
Scanner successfully IMLed, no action
(stop, go, connect, disconnect, reset)
performed and no scanner error detected:
scanner is initialized
Unused
HPTSS/ESS found present in the CDF
LA byte 3
x1
x identifies the type of LA:
1
TSS
2
HPTSS
3
TRSS
6
ESS
The second digit is always set to 01.
LA byte 4
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F to 15
Mismatch between CDF and data returned from
the scanner (MUX presence and EXTEND bit)
Bad IOC bus test
Error during loading of CSP load module
Bad CSP checkout result
Time out during IOH on CSP
Bad block transfer between CCU and CSP
Bad CSP initialization
Bad return from CHGCDLA access function
Bad selective POR
Invalid position on power block returned by CDF
Scanner responsible of time out at IOC bus test
Scanner with the same power source as one with
bad UC bus test return
Scanner which can not be powered ON
Scanner not accessible in CDS
Unused
DISK
see DISK bytes
1-2 for details
5 halfwords:
1: OPEN
2: READ
3: LOAD
4: WRITE
5: CLOSE
Chapter 11. Error Logging
11-69
Summary of Contents for 3745 Series
Page 2: ......
Page 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Page 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Page 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Page 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Page 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 708: ......
Page 711: ......
Page 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...