stops, the number of cycles is preserved, and an error code may be displayed by
pressing the 'GO' key.
If during a self-test, the remote DCE sends an alarm tone, this tone is ignored by
the DCE in self-test.
Local Self-Test for LIC Type 6
This tests checks the following components/functions:
Microprocessor
ROS
Internal and external RAM
NVRAM (RAM part and configuration parameters)
Read/write registers
DTE module
Line loop circuitry
SDLC adapter
Alarm signal (transcode test)
CSU (stress test).
This test is automatically performed at each power ON. In this case, a check of the
CMOS modules LSSD string hardware is added.
If an error is found during the tests of the configuration parameters in the NVRAM
(checksum error which could be due to a blank area), then:
1. A default configuration is transferred from the RAM in the NVRAM.
2. The indication is recorded for a future LPDA-2 report if applicable.
3. The LIC type 6 is put in idle mode.
4. A warning is displayed.
Remote Self-Test
Supervisory message
┌──────────────┐ ───────────────5
┌──────────────┐
│
│
│
5─────────┐ │
│
DCE
├───────────//───────────┤
DCE
│ │
Self-test
│
│
│
%─────────┘ │
└──────────────┘
%────────────────── └──────────────┘
Local
Supervisory message
Remote
A supervisory message is sent from the local DCE to the remote (along with the
DCE address). On reception of this message, the addressed DCE starts a self-
test (less than 5 s) and sends back the result of the test in a supervisory message.
During the test execution, 'WAIT' is displayed on the local and the remote DCEs, TI
is raised, RFS and CD dropped at the local and remote DTE interfaces, and the
DATA traffic through the DCEs is interrupted.
DSR drops at the local DCE, if DTR is OFF.
At the end, a report is displayed on the local DCE and normal background informa-
tion on the remote DCE.
If the request causes the remote DCE to fail, the alarm tone is sent, and a report is
displayed.
Chapter 4. Transmission Subsystem (TSS)
4-97
Summary of Contents for 3745 Series
Page 2: ......
Page 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Page 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Page 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Page 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Page 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 708: ......
Page 711: ......
Page 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...