If a non-productive time out occurs after the request, a report is displayed.
Local Status
┌──────────────┐
│
DCE
├─────────//─────────
└──────────┬───┘
│
│
6
Local status
When initiated on the local DCE, the following information is displayed:
Local line status (current quality, number of hits within the last 15 mn, warnings
logged, current receive level)
Local DTE interface status and activity.
Data traffic through the DCE is not interrupted. Normal operation take place at the
DTE interface and TI is not raised. Then this test displays line quality and received
level, until the 'STOP' key is pressed, or a 30 s time out is reached.
Any LPDA-2 command issued to the DCE from the DTE is ignored (TI is kept
OFF).
Remote Status
┌──────────────┐
┌──────────────┐
│
DCE
├───────────//───────────┤
DCE
│
└───────────┬──┘
%────── └──────────────┘
Local
│
Status
Remote
│
6
Remote status
When initiated on the local DCE, along with the remote DCE address, the following
information is received (within 5 s maximum) and displayed at local DCE in the
following sequence:
Remote line status (current quality, number of hits within the last 15 mn,
warnings logged, current receive level).
Remote DTE interface state and transition since the last request.
During execution, TI is raised, RFS and CD dropped at the local and remote DTE
interfaces, and the data traffic through the DCE is interrupted.
At local and remote DCE, DSR drops if DTR is OFF; otherwise, DSR is kept ON.
Digital Test (Transmit/Receive) for LIC Type 5
Loop test with a tributary station is performed in chopped carrier mode and half-
duplex protocol. This protocol allows different inbound and outbound speeds in the
control DCE of a multipoint network.
For each test 16 blocks (256 bytes each), are transmitted in each direction. The
blocks missed or in error, are counted as erroneous.
In point-to-point, the test is run in continuous carrier operation.
4-98
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Summary of Contents for 3745 Series
Page 2: ......
Page 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Page 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Page 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Page 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Page 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 708: ......
Page 711: ......
Page 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...