Contentions
Same as for LIC type 5; see page 4-78.
Note: If a function is selected while a loop (loop 3 or DDS loop) is being executed,
a message (BUSY TC ON or DDS LOOP ACTIVE) appears on the screen.
If TC raises after selection but before execution BUSY TC ON is displayed.
Unsolicited Messages
These messages appear on the screen, without any operator intervention. If a PKD
operator session is in progress the unsolicited messages are delayed. They can
appear only when the screen displays background information. For complete infor-
mation, refer to the
Configuration and Integration Guide.
LDM LINE DOWN or DDS LINE DOWN
Lack of receiver timing or error on received block.
DDS OOS or DDS OOF
DDS out frame or DDS out of service indication.
CMD FROM LINE
(2 s)
CMD FROM DTE
(2 s)
REM DSU/CSU FAILED
Stays on the screen until the operator presses EXIT. This
message is not displayed if the PKD was not present when
the condition occurred.
REM PWR LOSS
In point-to-point, this message remains until CD goes ON or
the operator presses EXIT. It appears as soon as the PKD
is present if CD is still 0.
KEY n STUCK
When the indicated key appears to be pressed during more
than 5 s. The message stays 10 s then the operator panel is
reinitialized. This indicates a mechanical or electrical
problem.
aa LIC6 FAILED
At power ON, the initial self-test failed.
DEFAULT CONFIG
Operator intervention is required to reconfigure the
DSU/CSU.
INV PATTERN RCV Invalid pattern received (ex: a DDS pattern in LDM mode).
TEST FROM HOST
A test has been initiated from the 3745.
WRONG SLOT
The cassette has been plugged in a wrong position.
MAND DDS LOOP
A mandatory DDS loop has been initiated from the DDS
(reversal polarity loop).
OPT DDS LOOP
An optional DDS loop has been initiated from the DDS
(bipolar code violation loop).
TEST FAILED
A manual self-test failed or a host self-test failed.
SELF TEST FAILED A self-test failed after a configuration change.
TEST OK
A self-test requested by the host is successful.
SELF TEST OK
A self-test is successful after a configuration change.
TEST OK NOWRP
A manual self-test without tel wrap plug is successful.
TEST OK WRAP
A manual self-test with tel wrap plug is successful.
DEFAULT CONFIG
Operation intervention is required to reconfigure the
CSU/CSU.
4-90
IBM 3745 Models 130, 150, 160, 170, and 17A: Hardware Maintenance Reference
Summary of Contents for 3745 Series
Page 2: ......
Page 12: ...x IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 14: ...xii IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 18: ...xvi IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 21: ...3745 Models 130 150 160 and 170 Data Flow Chapter 1 General Information 1 3 ...
Page 149: ...For RACs 241 to 244 ERR bits Data received from the adapter Chapter 3 Buses 3 57 ...
Page 166: ...4 14 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 169: ...Chapter 4 Transmission Subsystem TSS 4 17 ...
Page 322: ...6 28 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 348: ...7 26 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 625: ...The ESS in 3745 Models 130 150 160 and 170 Data Flow Chapter 12 Ethernet Subsystem ESS 12 3 ...
Page 674: ...X 6 IBM 3745 Models 130 150 160 170 and 17A Hardware Maintenance Reference ...
Page 708: ......
Page 711: ......
Page 712: ...IBM Part Number 03F5010 Printed in Denmark by IBM Danmark A S ð3F5ð1ð SY33 2ð66 4 ...