3. Basic Settings
25
4) Establish the setting in I/O Parameter No. 530 , 532.
The setting value should be the number of position data points for one axis. Set a number of
points with enough margin.
However, the maximum number of available position data points differs depending on the
setting in I/O Parameter No. 531. Refer to the table below and establish the setting not to
exceed the maximum values. Set the value in I/O Parameter No. 532 same as that in No.
530.
[I/O Parameter]
No.
Name
530
Max. Number of Extension Motion Control Position Data
Points to Use
532
Number of Points for Extension Motion Control Position Data
Definition
I/O Parameter
No.531
Max.
Number of
Position
Points
I/O Parameter
No.531
Max.
Number of
Position
Points
0
512 16
240
1
512 17
227
2
512 18
215
3
512 19
204
4
512 20
195
5
512 21
186
6
512 22
178
7
512 23
170
8
455 24
163
9
409 25
157
10 372
26 151
11
341 27
146
12 315
28 141
13 292
29 136
14 273
30 132
15 256
31 128
[Example] When I/O Parameter No. 531 = “9”
→
The maximum number of position data points for one axis should be “409”.
5) Transfer the changed parameters, write them in the flash ROM, and reboot the controller.
Click Transfer button.
ME0364-2B
Summary of Contents for RA Series
Page 2: ......
Page 4: ...ME0364 2B ...
Page 22: ...1 Outline of Extension Motion Control Feature 14 ME0364 2B ...
Page 40: ...3 Basic Settings 32 ME0364 2B ...
Page 150: ...5 Practical Settings 142 ME0364 2B ...
Page 170: ...6 Parameter Detail 162 ME0364 2B ...
Page 174: ...7 Details of Features 166 ME0364 2B ...
Page 184: ......
Page 185: ......