![IAI RA Series Instruction Manual Download Page 114](http://html.mh-extra.com/html/iai/ra-series/ra-series_instruction-manual_604006114.webp)
4. Operation Program
106
4.6. Sample Programs
4.6.1. Positioning Using Position Data
Program example
VEL
250
Set 200 mm/s for speed.
ACC
0.3
Set 0.3G for acceleration.
DCL
0.3
Set 0.3G for deceleration.
XAXS
00000011 11111111
It indicates Extension Motion Control Axis No. 0 to 9.
XSON
It turns on the servo on the indicated axis.
XMVP
0
It makes the master axis and slave axes have PTP
movement operation conducted to the synchronizing
start position (Position No. 0).
XAXS
00000000 00001111 It indicates Extension Motion Control Axis No. 0 to 3.
XMVP
1
It makes the indicated axis have PTP movement
operation conducted to Position No. 1.
XAXS
00000000 11110000 It indicates Extension Motion Control Axis No. 0 to 3.
XMVP
2
It makes the indicated axis have PTP movement
operation conducted to Position No. 1.
XAXS
00000011 00000000 It indicates Extension Motion Control Axis No. 8 to 9.
XMVL
3
It makes the indicated axis have PTP movement
operation conducted to Position No. 3.
EXIT
End the program.
ME0364-2B