4. Operation Program
108
4.6.3. Electronic Cam Synchronizing Operation
[Condition]
Master axis
Standard motion control axis No.2
Slave axis
extension motion control axis No.0, 1
Electronic CAM table
No.5
Stroke type
1 (Stroke End Position Indication)
Synchronization type
2 (Starts after reaching synchronizing start position,
executed only for one cycle)
[Program example]
VEL
100
It makes the movement speed of the master axis
set to 100mm/sec.
ACC
0.3
Set 0.3G for acceleration of master axis.
DCL
0.3
Set 0.3G for deceleration of master axis.
MOVP
10
It makes the standard motion control axis move to
Position No. 11.
LET
200
1 It makes Synchronization Type = 2 (Starts after
reaching synchronizing start position, executed
only for one cycle) set to Variable No. 200.
LET
201
0 It makes Master axis Type = 0 (Standard Motion
Control Axis) set to Variable No. 201.
LET
202
2 It makes Master axis No. = 2 set to Variable No.
202.
LET
203
5 It makes Electronic Cam Table No. = 5 set to
Variable No. 203.
LET
204
1 It makes Stroke Type = 1 (Stroke End Position
Indication) set to Variable No. 204.
LET
205
2 It makes Master axis Stroke Length Position
Storage Position No. = 2 set to Variable No. 205.
LET
206
0 It makes Slave Axis Stroke Length Position Storage
Position No. = 0 set to Variable No. 206.
LET
207
1 It makes Synchronizing Start Position Storage
Position No. = 1 set to Variable No. 207.
LET
208
0 It sets 0 to Variable No. 208 (Reservation Area)
LET
209
0 It sets 0 to Variable No. 209 (Reservation Area)
XCAS
0
200 It starts the synchronizing electronic cam operation
in Extension Motion Control Axis No. 0 with the
synchronizing electronic cam operation setting
indicated in Variable No. 200 to 209.
XCAS
1
200 It starts the synchronizing electronic cam operation
in Extension Motion Control Axis No. 1 with the
synchronizing electronic cam operation setting
indicated in Variable No. 200 to 209.
MOVP
11
It makes the standard motion control axis move to
Position No. 11.
EXIT
End the program.
ME0364-2B
Summary of Contents for RA Series
Page 2: ......
Page 4: ...ME0364 2B ...
Page 22: ...1 Outline of Extension Motion Control Feature 14 ME0364 2B ...
Page 40: ...3 Basic Settings 32 ME0364 2B ...
Page 150: ...5 Practical Settings 142 ME0364 2B ...
Page 170: ...6 Parameter Detail 162 ME0364 2B ...
Page 174: ...7 Details of Features 166 ME0364 2B ...
Page 184: ......
Page 185: ......