6. Parameter Detail
154
[13] Axis Use Method (Extension Motion Control Each Axis Parameter No. 1)
No.
Parameter Name
Unit
Input range
Initial value
(reference)
1
Axis Use Method
-
0 to 4
0
Establish the setting as shown below based on the way to use the subject axis.
Setting
value
Use Method
0
Not used
1
Slave driver control
2
Standard driver control
3
Drive Invalid Axis Control
4
Slave Driver Reserved Axis
[14] Slave Address (Extension Motion Control Each Axis Parameter No. 4)
No.
Parameter Name
Unit
Input range
Initial value
(reference)
4
Slave address
-
3 to FEEF
H
0
H
Set the slave addresses for the slave driver to be connected.
The slave addresses consist of 16 bits, “extension addresses” (upper 8 bits) and “station
addresses” (lower 8 bits). (As bit 16 to 31 are for reservation, set “0”.)
31
24
bits
23
16 15
8
Extension Address (Valid Range: 00H to FEH)
7
0
Station Address (Valid Range: 03H to EFH)
0
0
0
0
Station Assress
: Assign a peculiar address to each slave controller.
Extension Address : If several stations exist in the slave controller, a peculiar address can be
assigned to each station.
(Nore) It is necessary to assign in a row with “00H” as the start.
It is fixed “00H” for single-axis type RC controllers
(e.g. SCON-CA).
ME0364-2B
Summary of Contents for RA Series
Page 2: ......
Page 4: ...ME0364 2B ...
Page 22: ...1 Outline of Extension Motion Control Feature 14 ME0364 2B ...
Page 40: ...3 Basic Settings 32 ME0364 2B ...
Page 150: ...5 Practical Settings 142 ME0364 2B ...
Page 170: ...6 Parameter Detail 162 ME0364 2B ...
Page 174: ...7 Details of Features 166 ME0364 2B ...
Page 184: ......
Page 185: ......