2.3. Example for Emergency Stop System Construction
Caution : Configure the emergency stop by connecting the XSEL controller and each of
RC controllers to the same system such that the emergency stop command is
input to the XSEL controller and each RC controller at the same time.
Error No. C65 “Servo on/off Logic Error” or Error No. E58 “Servo on/off Timeout
Error” will occur when only the RC controller side comes into the emergency
stop condition while the servo for a command from the XSEL controller is on.
XSEL Controller
SCON Controller
ACON/PCON Controller
ME0364-2B