Function description
Chapter 3
OPERATION MANUAL
V2.4.0en/22.07.20//17.12
Unistat® T300 Series
41
3.4
“Pilot ONE®” controller
The
»”Unistat Control ONE” and “Pilot ONE”«
illustration can be found on page 6.
The basic version of “Pilot ONE” (Basic) can be upgraded in three stages (from “Basic” to “Exclusive”,
from “Exclusive” to “Professional”, and from “Professional” to “Explore”).
3.4.1
Functional overview of “Pilot ONE®”
Temperature control units / E-grade
E-grade
Basic
E-grade
Exclusive
E-grade
Profes-
sional
Brewing thermostats
–
X
O
Unistat temperature control units
–
–
X
UniCAL
–
–
X
Other temperature control units
X
O
O
E-grade “Explore”
(only for “Unistat”-series temperature control units)
The E-grade includes E-grade “Professional” functionalities.
In addition it includes:
– Sensor calibration for return sensor
– Return temperature display
– Display of performance (estimated or calculated from volume flow)
– Display mode “Explore” instead of “numerically large”
– PB commands correspond to DV-E-grade, except: Temperatures only
in 0.01
°C and volume flows only in 0.1
l/min.
–
–
O
E-grade “DV-E-grade”
– All interface commands are enabled.
– Temperatures in 0.001 C, volume flows in 0.001 l/min possible (cf. E-
grade Explore)
Note:
Only the interface commands are enabled, not the correspond-
ing menu items in Pilot ONE!
O
O
O
E-grade “OPC-UA”
– OPC-UA interface via Ethernet.
This E-grade additionally includes DV-E-grade functionalities.
O
O
O
X = Standard equipment, O = optional, – = not possible
Function
E-grade
Basic
E-grade
Exclusive
E-grade
Professi
-
onal
Temperature control
Controller parameterization: predefined
/ TAC
X/–
–/X
–/X
Find parameters: Fast Identification / With Preliminary Test / Estimate
Control Parameters
–/–/X
X/X/–
X/X/–
Sensor calibration for control sensor
: x -point
2
5
5
Monitoring: Low level and overtemperature
X
X
X
Adjustable alarm thresholds
X
X
X
VPC
X
X
X
Ventilation program
X
X
X
1
TAC function available as a 30 day evaluation version.
2
True Adaptive Control.
3
Internal Pt100 and External Pt100.
4
For temperature control units with integrated overtemperature protection.
5
For units with variable-speed pump or external bypass.
Overview of the
E-grade variants
Overview of
E-grade functions
Summary of Contents for Pilot ONE Unistat T3*0
Page 1: ...Unistat T300 Series...
Page 2: ......
Page 3: ...OPERATION MANUAL Unistat T300 Series...
Page 4: ......
Page 7: ...OPERATION MANUAL V2 4 0en 22 07 20 17 12 Unistat T300 Series 7 Layout of the Home screen...
Page 99: ...Annex Chapter 9 OPERATION MANUAL V2 4 0en 22 07 20 17 12 Unistat T300 Series 99 9 Annex...